Clamp Meter
MODEL 2000/2003

  • DC/AC 2000A
  • Cable f55mm, Bus Bar 72mm(D) x 22mm(W)
  • True RMS (2000)
  • Average Sensing (2003)
  • DCA One Touch Zero
  • Auto Range A, V, W
  • Continuity
  • Max/Min/Hold
  • Relative Measurement

  • PROVA 2000/2003

    Specifications for PROVA 2000/2003 (23oC+/-5oC)

    DC Current (Autorange & Manual)
    Range Resolution Accuracy Overload Protection
    400A 0.1A +/- 1.5% +/- 3dgts 3000A
    2500A 1A +/- 1.5% +/- 3dgts 3000A

    AC Current (Autorange & Manual, True RMS for PROVA 2000)
    Range Resolution Accuracy Overload Protection
    50/60Hz 40-400Hz
    400A 0.1A +/- 1.5% +/- 5dgts +/- 2.0% +/- 5dgts 3000A
    2100A(0-1000) 1A +/- 2.0% +/- 5dgts +/- 2.5% +/- 5dgts 3000A
    2100A(1000-2100) 1A +/- 2.5% +/- 5dgts +/- 3.0% +/- 5dgts 3000A

    Current Analog Output (Overload Protection 600V)
    Range Output Accuracy Overload Protection
    400A 1mV/A +/- 2.5% +/- 0.5A 600VAC
    2500A 1mV/A +/- 2.5% +/- 5A 600VAC

    DC Voltage (Autorange & Manual,
    Overload Protection 800VAC for all ranges)
    Range Resolution Accuracy Input Impedance
    400mV 0.1mV +/- 1.0% +/- 3 dgts 10MW
    4V 0.001V +/- 1.0% +/- 3 dgts 5MW
    40V 0.01V +/- 1.0% +/- 3 dgts 5MW
    400V 0.1V +/- 1.0% +/- 3 dgts 5MW
    600V 1V +/- 1.0% +/- 3 dgts 5MW

    AC Voltage (Autorange & Manual, True RMS for PROVA 2000,
    Input Impedance 5MW for all ranges)
    Range Resolution Accuracy Overload Protection
    4V 0.001V +/- 1.5% +/- 5dgts 800VAC
    40V 0.01V +/- 1.5% +/- 5dgts 800VAC
    400V 0.1V +/- 1.5% +/- 5dgts 800VAC
    600V 1V +/- 1.5% +/- 5dgts 800VAC

    Resistance (W) (Autorange & Manual,
    Open Circuit Voltage<=0.5V)
    Range Resolution Accuracy Overload Protection
    400W 0.1W +/- 1.5% +/- 3dgts 600VAC
    4KW 1W +/- 1.5% +/- 3dgts 600VAC
    40KW 10W +/- 1.5% +/- 3dgts 600VAC
    400KW 100W +/- 1.5% +/- 3dgts 600VAC
    4MW 1KW +/- 1.5% +/- 3dgts 600VAC
    40MW 10KW +/- 1.5% +/- 3dgts 600VAC

    Audible Continuity
    Range Continuity Beeper Open Circuit Voltage Overload Protection
    400W <=40W (approx.) <=0.5V 600VAC

    Diode Test
    Range Resolution Accuracy Overload Protection
    3V 0.001V +/- 2.5% +/- 5dgts 600VAC

    Hz
    Range Resolution Accuracy Sensitivity Overload Protection
    100-1000KHz 0.01-100Hz +/- 0.5% +/- 2dgts 10mV/0.1V/1V AC 600V

    Gerenal Specification:
    Jaw Opening Cable f55mm
    Bus Bar 65mm(D)x24mm(W)
    Power Source One 006P 9V or IEC 6F22
    or NEDA 1604 Battery
    Operating Temperature 0o to 40oC (32oF to 104oF)
    Operating Humidity Less than 80% RH
    Dimensions 271mm(L)x112mm(W)x46mm(H)
    10.7"(L)x4.4"(W)x1.8"(H)
    Weight 647g/22.8 oz (Battery included)