AC Clamp Meter
MODEL TES-3040
EN61010-1
600V INSTALLATION VAT III
POLLUTION DEGREE 2
  • 3-3/4 Digital LCD with bar-graph
  • Auto-power off with Data Hold and MAX/MIN
    aa-mode
  • Zero Adjustment/Relative Reading

  • TES-3040

    Specifications for TES-3040

    DC Voltage(AC/DC)
    Range: DC - 400mV/4V/40V/400V/600V
    aaaaaa-AC - 4V/40V/400V/600V
    Accuracy: DC - 0.75% rdg + 2 dgts
    aaaaaaaaa-AC - 1.5%rdg + 5dgts
    Resolution: 0.1mV(DC); 0.001V (AC)
    Input Impedance: 11MW
    Overload Protection: DC 1100V & AC 800V

    Ohms (Resistance)
    Range: 400W/4KW/40KW/400KW/4MW/40MW
    Accuracy: 1% rdg + 5dgts
    Resolution: 0.1W
    Overload Protection: 600Vrms
    Max Open Circuit Voltage: 0.5VDC

    Current(AC)
    Range: 400/1000A
    Accuracy: 2% rdg + 10 dgts
    Resolution: 0.1A
    Overload Protection: 1100A

    Audible Continuity
    Continuity beeper below 40W
    Max Open Circuit Voltage: 0.5V
    Overload Protection: 600Vrms

    Frequency (Hz)
    Range: 100Hz/1KHz/10KHz/100KHz/800KHz
    Accuracy: 0.5% rdg + 5dgts
    Resolution: 0.01Hz
    Max Input Sensitivity: 100mV
    Overload Protection: 1100A/600Vrms

    Diode Test:
    Resolution: 0.001V
    Accuracy(50Hz-60Hz): 1% rdg + 2 dgts
    Overload Protection: 600Vrms
    Numerical Display:
    3 3/4 digit liquid crystal display (LCD) maximum
    reading 3999
    Sampling Rate:
    20 times/sec (Bargraph)2 times /sec (Digital Display)
    Power Source:
    one 006p; 9V or IEC 6F22 or NEDA 1604 Battery
    Operating/Storage/Temperature & Humidity:
    0oC to 40oC (32oF to 104oF) < 80%RH
    -10oC to 60oC (14oF to 140oF)< 70%RH
    Dimensions: 239(L) x 66(W) x 34(H) mm
    Weight: Approx. 365g

    TES Electrical Electronic Corp.
    No. 57 Jen-Ai Road Sec. 2 TAIPEI, TAIWAN.
    TEL : 886-2-2393-9142
    FAX : 886-2-2395-9146
    E-mail : [email protected]

    [PREVIOUS PAGE]
    [NEXT PAGE]
    [INDEX]
    [HOME]