MODEL TES-3090 EN61010-1 600V INSTALLATION VAT�� POLLUTION DEGREE2 |
Specifications for TES-3090
AC Current Range: 40 / 400A Resolution: 0.01A Accuracy: +/- (2%rdg + 10dgts) (50 to 60Hz) Overload protection: 600Arms AC Voltage Range: 40 / 400V Resolution: 0.01V Accuracy:+/- (1.5%rdg + 10dgts) (40 to 450Hz) Overload protection: 660Vrms DC Voltage Range: 40 / 400V Resolution: 0.01V Accuracy:+/-(1%rdg + 5dgts) Overload protection: 660Vrms Ohms (Resistance) Range: 400W Accuracy: +/- (1%rdg + 5 dgts) Resolution: 0.1W Overload protection: 660Vrms |
Continuity Beeper: Sound Level -below 40W Max Open Circuit Voltage: -1.1~-1.3V Numerical Display : 3 3/4 digit liquid crystal display (LCD) maximum reading 3999 Power Source:Two 1.5V, LR-44 battery Auto power off: 30 minute Battery Life:200hr approx. Operating Temperature and Humidity: 0oC to 40oC (32oF to 104oF) below 80�MRH. Storage Temperature and Humidity: -10oC to 60oC (14oF to 140oF) below 70�MRH. Dimensions: 187(L) x 45(W) x 30(H)�P Weight: Approx. 185 g Jaw Opening Diameter: Cables 27 mm Accessories: Carrying case, Battery & Instruction Manual, Test Lead. |
TES Electrical Electronic Corp.
No. 57 Jen-Ai Road Sec. 2 TAIPEI, TAIWAN.
TEL : 886-2-2393-9142
FAX : 886-2-2395-9146
E-mail : [email protected]
|
|
|
|